SLIDING DOORS
DIVA Sliding Door
Managing with intelligence ingoing and outgoing movements, these doors are particularly convenient for all public places with heavy traffic and where users' safety depends on traffic flow.
PERFORMANCE, COMFORT and SAFETY
- Digital control panel and self-controlled luminosity
- Incorporated traffic analyser
- Infrared remote control
- Auto-control infrared barrier
- Locking device through infrared key
- Lighted display incorporated into the cover
- Airlock management...
The wide choice of finishes, leaves and glazing… and the easy installation in many configurations let the architects create an entrance according to their imagination and provide safer and more comfortable conditions to customers.
| Number of leaves | 1 or 2 |
| Casing Dimensions Standard / Reinforced | 150 x 200 mm / 175 x 200 mm |
| Opening width min/max - door 1 leaf | 750 / 1500 mm |
| Opening width min/max - door 2 leaves | 900 / 2400 mm |
| Maximum opening height (Recommended) | 2500 mm |
| Maximum leaf weight | 1 x 150kg / 2 x 100kg |
| Adjustable Opening speed | 0,1 to 1 m/s |
| Adjustable Closing speed | 0,1 to 0,6 m/s |
| Adjustable Opening time | 1 to 15 s |
| Adjustable Opening force | 6 to 25 daN |
| Adjustable Closing force | 6 to 15 daN |
| Environment and electrical connections | |
| Power supply | Mains 50-60 Hz, 230 V + 10 % with earth. |
| Power Consumption max / average | 500 W / 40W |
| Standards | |
| EC | EN 60 335 - 1, EN 50 081 - 1, EN 50 082 – 2 |
| TUV | |